Description

David medical back circle

The David Device Compass is a specially developed spinal column concept consisting of 5 devices, which are coordinated with each other. Biomechanics have analysed the stereotypes of the torso-stabilizing muscles and have reconstructed the David systems exactly to these movement sequences. No other therapy device combines this precise rotary axis positioning with the maximum load capacity of the spinal column.

FPZ back therapy can be billed via this equipment circle. (certified)

The equipment was purchased in 2013, overhauled and regularly serviced. They are technically and optically without defects and function excellently.

1 David abdominal flexion F 130

The flexion device fixes the axis of rotation exactly on the axis between L3/L4, the pivot point of the flexion movement in the lumbar section of the spine. The Hip Fix allows only minimal use from the lower extremities.

The movement amplitude detects movements between 53/0/-35°. A limitation is possible both mechanically and optically. The resistors are dosed in minimum steps of 2.50 kg, starting with a maximum load of 100.00 kg and ending with a maximum load of 100.00 kg.

The system can be operated both by a therapist and by the patient.

2 David back extension F 110

The extension device fixes the axis of rotation exactly on the axis between L3/ L4, the pivot point of the flexion movement in the lumbar section of the spine. The Hip Fix allows only minimal use from the lower extremities. The movement amplitude detects movements between 53/0-35°. A limitation is possible both mechanically and optically. The resistors are dosed in minimum steps of 2.50 kg, starting with a maximum load of 100.00 kg and ending with a maximum load of 100.00 kg. The system can be operated both by a therapist and by the patient.

3 David Lateral Flexion F 150

This device is a combination device of the lateral inclination of the spine to the right and left. The rotation axis is between L3 and L4 and is adjusted via the seat height adjustment. The movement amplitude detects movements between 50/0/.50°. A limitation is possible both mechanically and optically. The resistors are dosed in minimum steps of 2.50 kg, starting with a maximum load of 100.00 kg and ending with a maximum load of 100.00 kg. Diagnostics with David EVE

4 David Thoracic Rotation F 120

This torsion device is unique. No other system allows the spine to rotate in such a functional way. LWS/BWS and pelvis twist against a fixed upper body exactly in the axis of the spine. The movement amplitude detects movements between 70/0/-70°. A limitation is possible both mechanically and optically. The resistors are dosed in minimum steps of 2.50 kg, starting with a maximum load of 100.00 kg and ending with a maximum load of 100.00 kg. Diagnostics using David EVE.

5 David Cervicales Combination System F 140

This device enables use in the four main directions of movement of the cervical spine.

Movement directions:

  • extension
  • inflection
  • Lateral flexion right and left


The height of the axis of rotation is between C6 and C7 and the depth in the direction of movement is directly on the spine.

The movement amplitude detects movements between 40/0/-40°. A limitation is possible both mechanically and optically. The resistors are dosed in minimum steps of 1.00 kg starting up to a maximum load of 25.00 kg.

The system can be operated both by a therapist and by the patient.